PRODUCT / 03 / Prefabricated Substations
Prefabricated Substation
Compact factory-assembled substation integrating the high voltage compartment, transformer compartment and low voltage compartment in one enclosure, verified to IP44 and IK10.
Standards referenced for project review, not evidence of product certification:
- IEC 62271-202
- Structure
- Three-compartment integrated (HV / transformer / LV)
- Type tests
- Insulation, grounding and temperature-rise tests qualified
- Noise level
- ≤ 45 dB(A) (measured 37 dB(A))
- Configurable
- Rated voltage, transformer capacity, switchgear configuration, enclosure dimensions and protection scheme engineered per project
- Enclosure protection
- IP44
- Mechanical impact resistance
- IK10
العرض الهندسي
محطة فرعية بثلاث حجرات
ملخص مرئي لبيانات المصدر المنشورة. لا يحل محل الجدول الفني الكامل أو تأكيد المشروع.
- حماية الغلاف
- IP44
- الصدمة الميكانيكية
- IK10
- التهيئة
- خاص بالمشروع
Product description
Compact factory-assembled substation integrating the high voltage compartment, transformer compartment and low voltage compartment in one enclosure, verified to IP44 and IK10.
Features
- Three-compartment integrated structure
- Compact footprint and convenient transportation
- Factory prefabrication for faster on-site installation
- Suitable for industrial, commercial and infrastructure distribution systems
- Enclosure protection verified to IP44
- Mechanical impact resistance verified to IK10
Test values stated in the product flyer
- Measured noise
- 37 dB(A)
- Enclosure protection
- IP44
- Noise level (requirement)
- ≤ 45 dB(A)
- Mechanical impact resistance
- IK10
- Enclosure mechanical strength
- 2500 N/m² minimum; measured 2600 N/m²
- Insulation / grounding / temperature-rise tests
- Qualified
Technical parameters
| Parameter | Value |
|---|---|
| Structure | Three-compartment integrated (HV / transformer / LV) |
| Type tests | Insulation, grounding and temperature-rise tests qualified |
| Noise level | ≤ 45 dB(A) (measured 37 dB(A)) |
| Configurable | Rated voltage, transformer capacity, switchgear configuration, enclosure dimensions and protection scheme engineered per project |
| Enclosure protection | IP44 |
| Mechanical impact resistance | IK10 |
| Enclosure mechanical strength | ≥ 2500 N/m² (measured 2600 N/m²) |
Parameters are taken from the manufacturer product sheet. Final ratings are confirmed against the project specification before order.
سياقات التطبيق الموثقة
تعرض هذه الروابط أساس الأدلة المرتبط حالياً بهذا المنتج. وهي نقاط بدء للمراجعة الهندسية وليست مراجع لمشاريع أو توصيات.
Frequently asked questions
What is integrated in the substation?
The platform combines high-voltage, transformer and low-voltage compartments in one factory-assembled enclosure.
Which verified enclosure data is available?
The supplied flyer states IP44 enclosure protection and IK10 mechanical impact resistance. It also reports 37 dB(A) measured noise and 2600 N/m² measured enclosure mechanical strength.
Are voltage and transformer capacity fixed?
No. Rated voltage, transformer capacity, dimensions, protection scheme and final configuration are project-specific and confirmed during engineering.
Which standards apply?
Review IEC 62271-202 as applicable references. The exact standard scope and supporting test evidence must be confirmed for the quoted configuration.
الخطوة التالية
Specify the equipment.
فئة الجهد والتيار المقنن ومستوى القصر وبيئة التركيب والمعايير التي طُرح مشروعك وفقاً لها.